| Clock
Stability 1.544MHz +/-30ppm, 0 to 50C.
Power: -48Vdc,
Station Battery, 10 Watts.
Dimensions: 1.75"H
x 15"W x 9"D
19" and 23" Rack Mount Standard.
Weight: 4 Pounds
Temperature: 0C
to 50C Operating, -25C to 75C Storage
|
| 56
DSX-1 Outputs on rear panel wirewrap connectors, 0.156" pin spacing,
optional AMP champ and DB-26 connectors. Outputs are organized into
7 groups of 8 outputs each. Each group may independently be set for
framing, patterns, coding and error insert.
1 DSX-1 Bantam output
on front panel, independently programmable. DSX-1 Outputs CB-119
Compatible.
Fail N.O. and N.C. contacts
for power or internal circuitry fail, rear panel terminal block
connection.
|
| Group
Select 1 to 8 (to select the 7 rear panel output groups or front
panel output to be configured).
Pattern QRSS, all
ones, 3 in 24, programmable 1 and 2 (Prog 1 defaults to all O's
and Prog 2 defaults to 55 Octet), and Thru(data recovered from DS-1
Input).
Framing SF, ESF,
or unframed.
Coding AMI or B8ZS.
|
Group
Select 8 Segment Display
Frame Mode SF,
ESF, Off.
Pattern QRSS, 1's,
3in24, PRG1, PRG2, THRU.
Code AMI, B8ZS.
Error Insert OFF,
Single, 2x10-4, 2x10-6, 1x10-6, 1x10-7.
Fail (Internal
circuit failure).
External Clock
On.
Remote On Operation
via RS-232C.
|
REFERENCE
DS-1 INPUT
DSX-1 or DSX-1 Monitor Level terminal block connections.
RS-232C I/O DB-9
Male, 8 data bits, no parity, 1 start and 1 stop bit, 1200/2400/4800/9600
baud.
|