ISDN
BRI Turn-Up Using the TSI-1569
|
|
1.
|
Use
with any portable ISDN BRI Test Set.
|
|
2.
|
The
TSI-1569 is installed permanently in the Central Office (CO)
in a 19/23-inch rack. The CO technician will assign a callback
number with a rollover feature capability according to the
switch translation table. This number will allow the field
test technician to dial to the TSI-1569, once accessed the
TSI-1569 will allow the technician to test and turn up the
ISDN BRI line, by ringing the portable ISDN BRI test set,
setting up loopback and allowing for BERT testing.
|
|
3.
|
Set
the callback number in the TSI-1569 by typing table phone-num
callback. This setup will be done once the TSI-1569 is installed
in the CO.
|
|
4.
|
Go
off hook in the portable ISDN BRI test set. A dial tone should
be heard.
|
|
5.
|
Dial
the TSI-1569 CALLBACK number.
|
|
6.
|
The
Model 1569 will automatically respond with a tone acknowledging
the connection and providing a loopback for BERT test.
|
|
7.
|
The
technician can start a BERT test.
|
|
8.
|
If
the calling number is not passed to the TSI-1569 it will respond
with an alarm audible tone then will go into a loopback for
BERT testing.
|
|
9.
|
Twenty-three
(23) separate and simultaneous ISDN BRI Turn-Ups can take
place using the TSI-1569.
|
|
10.
|
To
verify caller ID or ANI after the tone is heard, the technician
should hang up by going ON HOOK with the portable ISDN-BRI
test set.
|
|
11.
|
The
TSI-1569 then places a call back to the portable ISDN BRI
test set.
|
|
12.
|
When
the portable ISDN BRI test set answers, the TSI-1569 will
respond with a tone to acknowledge the connection, then enter
a loopback state allowing the technician to use the BERT feature
of the portable ISDN BRI test set to verify the line connection.
|