Power
Green LED indicates -48Vdc applied.
DS-1
Switch LOS Red LED indicates input DS-1 signal from network
not detected.
DS-1
Switch Error Red LED indicates input DS-1 signal from network
is making errors.
DS-1
DXC LOS Red LED indicates input DS-1 signal from terminal (Thru
and Cross Connect Modes only) not detected.
DS-1
DXC Error Red LED indicates input DS-1 signal from terminal
(Thru and Cross Connect Modes Only) is making errors.
Master
indicates the TSI-1569-2 Card is performing as a Master unit (23B
+ D).
Active
Green LED indicates one or more of the DS-0 B-channels are active.
Mode
TEST, THRU, CROSS CONNECT indicates the TSI-1569-2 Card is operating
in the Test, Thru or Cross Connect mode.
Alarm
Red LED indicates DS-1 LOS, Frame Loss, excessive DS-1 error rate
or internal failure.
|
Ethernet
10Base2 and 10BaseT for SNMP and TELNET sessions.
Chassis
0-5 rotary switch for setting chassis number in the Cross Connect
Mode.
B
Switch DS-1 In/Out B Card, Network side, screw terminal blocks,
DS-1 Levels, +6dB DSX to -30dB DSX.
B
DSX DS-1 In/Out B Card, Terminal side, (Thru and Cross Connect
Modes only) screw terminal blocks, DS-1 Levels, +6dB DSX to -30dB
DSX.
B
RS-232C B Card DB-9 Male, 1 Start Bit, 1 Stop Bit, 8 Data Bits,
No Parity.
B
Power: B Card power, screw terminal block -48VDC 20 Watts.
Baud
Rate: Switch selectable 2400, 9600, 19200, 38400 baud. Selects
rate for A RS-232C and B RS-232C.
S/T:
ISDN BRI S/T Interface for future option.
Handset
connection for an optional handset.
Alarm
Contacts NC, NO and Common indicates A or B Card DS-1 LOS, excessive
DS-1 error rate or Card failure.
A
Power: A Card power, screw terminal blocks -48VDC 20 Watts.
A
RS-232C A Card DB-9 Male, 1 Start Bit, 1 Stop Bit, 8 Data Bits,
No Parity.
A
Switch DS-1 In/Out A Card, Network side, screw terminal blocks,
DS-1 Levels, +6dB DSX to -30dB DSX.
A
DSX DS-1 In/Out A Card, Terminal side, (Thru and Cross Connect
Modes only) screw terminal blocks, DS-1 Levels, +6dB DSX to -30dB
DSX.
Termination:
Switch terminates the RS-485.
RS-485
RJ-45 connectors, RS-485 serial interface allows a card with ISDN
PRI D channel (NFAS) to control 4 additional chassis each with two
TSI-1569-2 cards when operating in the Cross Connect Mode.
|