TSI-1567 APPLICATION CODE INSTALLATION PROCEDURE The following procedure requires Procomm Plus or equivalent to perform the TSI-1567 applications code download. Other communications programs could be used if the configuration is setup accordingly. 1. Configure Procomm Plus - Go to Setup Menu (Alt-S) Select Protocol Options Select General Options Set Abort Xfer if CD Lost = no Select Protocol Options Select ASCII Protocol Set Char Pacing = 0 msecs Set Line Pacing = 0 tenths of a sec Set Pace Character = 62 (use '>' as pace character) Set CR Translation (Upload) = None Set LF Translation (Upload) = STRIP Escape out 2. Connect the computer to the TSI-1567 RS-232C interface and observe the 1567 prompt. The computer must be operating at the TSI-1567 baud rate. 1567> 3. Type "$$DOWNLOAD" at the prompt and enter. 1567>$$DOWNLOAD 4. The TSI-1567 should responds as follows: Download Help HELP Display this screen of commands ECHO Turn character echo ON or OFF ERASE Erase all the Main FLASH blocks ERASE Erase specified portions of FLASH memory LOAD Erase & start download of Motorola S-record file LOADNE Start download of s-records, but NO erase of FLASH END End download of S-records STATUS Show Status of downloaded code DUMP addr Dump bytes starting at the specified hex address WB addr value Write 8-bit hex value at specified hex address WW addr value Write 16-bit hex value at specified hex address PW addr value Program 16-bit hex value in Flash at hex address GO Start execution of downloaded code Download Version : V1.05, Jan 28, 1995 Application code : Installed & Confirmed Installed Checksum : 05630582 Computed Checksum : 05630582 Bytes of Code : 265810 User Dload Request : No Trap Occurred : No Dnld> 5. Type LOAD at the "Dnld>" prompt. Watch FLASH erase messages. Special "->" prompt should appear as follows: Erasing ... Param Block 1, 2 Main Block 1, 2, 3, 4 -> 6. Upload FLASH (this requires approximately 10 minutes at 38.4K baud) Page Up ASCII protocol A:1567_XXX.hex (Refer to disc for value of XXX) (Assumes the upload disc is in A: drive) ->S00B0000313536372E6F75749B . . -S804000200F9 7. After the last S-record is uploaded, the "Dnld>" prompt should return. Dnld> 8. Type "GO" to run newly loaded application code. Dnld>GO Memory Tst : Bank 1 Bank 2 Bank 3 Bank 4 Loading : Xilinx Framer Rx DSP Tx DSP ATS0=1E0Q1&D0X4S2=43 1567> 9. Type "CHECKSUM" to verify "Installed checksum" and "Computed checksum" are equal. 1567>CHECKSUM Installed Checksum : 0554B233 Computed Checksum : 0554B233 10. Type "CONFIRM" so code will automatically load next time at power on. 1567>CONFIRM Downloaded Code Confirmed - Will load automatically next time. 11. The software upgrade is complete. 12. Type "sys arrow off" to configure for Hekimian: 1567>sys arrow off If you experience a problem call: Ron Burgess TELESYNC, Inc. 770-246-9662 or Email: support@telesync.com