TSI-2069 APPLICATION CODE INSTALLATION PROCEDURE The following procedure requires Procomm Plus or equivalent to perform the TSI-2069 applications code download. Other communications programs could be used if the configuration is setup accordingly. 1. Configure Procomm Plus - Go to Setup Menu (Alt-S) Select Protocol Options Select General Options Set Abort Xfer if CD Lost = no Select Protocol Options Select ASCII Protocol Set Char Pacing = 0 msecs Set Line Pacing = 0 tenths of a sec Set Pace Character = 62 (use '>' as pace character) Set CR Translation (Upload) = None Set LF Translation (Upload) = STRIP Escape out 2. Connect the computer to the TSI-2069 RS-232C interface and observe the 2069 prompt. The computer must be operating at the TSI-2069 baud rate. 2069> 3. Type "$$DOWNLOAD" at the prompt and enter. 2069>$$DOWNLOAD 4. The TSI-2069 should responds as follows: HELP Display this screen of commands ECHO (ON,OFF) Turn character echo ON or OFF ERASE Erase all FLASH blocks for A & B ERASE (A,B) Erase all FLASH blocks for A or B ERASE (P1,...,P4,M1,...,M8) Erase specified FLASH blocks LOAD Erase & start download of Motorola S-record file STATUS Show Status of downloaded code RB addr Read bytes starting at specified hex address WB addr value Write 8-bit hex value at specified hex address WW addr value Write 16-bit hex value at specified hex address GO Start execution of downloaded code Bootstrap Version : V1.09, Nov 26, 1996 Application code : Installed & Confirmed Expected Checksum : 0B622324 Actual Checksum : 0B622324 Bytes of Code : 503942 User Dload Request : No Trap Occurred : No Dnld> 5. Type LOAD at the "Dnld>" prompt. Watch FLASH erase messages. Special "->" prompt should appear as follows: Dnld>LOAD Erasing ... Param Block 1, 2 Main Block 1, 2, 3, 4 Boot Block 2 Param Block 3 4 Main Block 5, 6, 7, 8 -> 6. Upload FLASH (this requires approximately 15 minutes at 38.4K baud) Page Up ASCII protocol A:2069_XXX.hex (Refer to disk for value of XXX) (Assumes the upload disc is in A: drive) ->S00B0000313536372E6F75749B . . -S804000200F9 7. After the last S-record is uploaded, the "Dnld>" prompt should return. Dnld> 8. Type "GO" to run newly loaded application code. Dnld>GO Memory Test : Bank 1 Bank 2 Dual Port NV RAM EEPROM Fetch : Successful Init Ports : Completed Led Test : Completed Checking : HDLC_1 HDLC_2 BRI Loading : XlnxA XlnxB Loading : Processor A Ethernet : Initialized ATS0=1E0Q1&D0X4S2=43 2069> 9. The software upgrade is complete. If you experience a problem call: Ron Burgess TELESYNC, Inc. 770-246-9662 or Email: support@telesync.com